Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23.630
Filtrar
1.
Biosens Bioelectron ; 256: 116260, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38613935

RESUMO

Various bioelectronic noses have been recently developed for mimicking human olfactory systems. However, achieving direct monitoring of gas-phase molecules remains a challenge for the development of bioelectronic noses due to the instability of receptor and the limitations of its surrounding microenvironment. Here, we report a MXene/hydrogel-based bioelectronic nose for the sensitive detection of liquid and gaseous hexanal, a signature odorant from spoiled food. In this study, a conducting MXene/hydrogel structure was formed on a sensor via physical adsorption. Then, canine olfactory receptor 5269-embedded nanodiscs (cfOR5269NDs) which could selectively recognize hexanal molecules were embedded in the three-dimensional (3D) MXene/hydrogel structures using glutaraldehyde as a linker. Our MXene/hydrogel-based bioelectronic nose exhibited a high selectivity and sensitivity for monitoring hexanal in both liquid and gas phases. The bioelectronic noses could sensitively detect liquid and gaseous hexanal down to 10-18 M and 6.9 ppm, and they had wide detection ranges of 10-18 - 10-6 M and 6.9-32.9 ppm, respectively. Moreover, our bioelectronic nose allowed us to monitor hexanal levels in fish and milk. In this respect, our MXene/hydrogel-based bioelectronic nose could be a practical strategy for versatile applications such as food spoilage assessments in both liquid and gaseous systems.


Assuntos
Técnicas Biossensoriais , Nariz Eletrônico , Técnicas Biossensoriais/métodos , Animais , Gases/química , Gases/análise , Aldeídos/química , Análise de Alimentos/instrumentação , Análise de Alimentos/métodos , Cães , Receptores Odorantes/química , Humanos , Leite/microbiologia , Leite/química , Desenho de Equipamento , Odorantes/análise
2.
J Hazard Mater ; 470: 134077, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38574654

RESUMO

In this study, we analyzed the occurrence and distribution of 11 benzophenone-type ultraviolet filters (BPs) in 893 food samples spanning 7 food categories in Taiwan. We conducted a Monte Carlo simulation to determine the carcinogenic and noncarcinogenic risks of BPs. The results indicated that cornflakes had the highest mean level of BPs (103 ng/g), followed by bread (101 ng/g) and pastries (59 ng/g). BP was the most prevalent category, followed by 4-methylbenzophenone (4-MBP), 2-hydroxybenzophenone, and benzophenone-3. Estimation of the lifetime cancer risk (LTCR) of BP (average life expectancy of 80 years) placed them in the 50th and 97.5th percentiles [P50 (P97.5)] LTCR of 1.9 × 10-7 (5.7 × 10-6), indicating that BP in food poses a low renal hazard to the Taiwanese population. The noncarcinogenic risk of BPs was evaluated using a hazard quotient and combined margin of exposure (MOET), revealing a P50 (P97.5) hazard index of < 1 for BP, 4-MBP, and methyl-2-benzoylbenzoate. Although the P50 MOET values for all age groups were within the moderate range of concern, with a more conservative extreme (P2.5), the MOET values for the 0-3, 3-6, and 6-12 age groups fell below 100, indicating a high concern for renal degeneration and hyperplasia.


Assuntos
Benzofenonas , Contaminação de Alimentos , Benzofenonas/análise , Benzofenonas/toxicidade , Taiwan , Humanos , Medição de Risco , Contaminação de Alimentos/análise , Protetores Solares/análise , Protetores Solares/toxicidade , Método de Monte Carlo , Análise de Alimentos
3.
Shokuhin Eiseigaku Zasshi ; 65(2): 25-30, 2024.
Artigo em Japonês | MEDLINE | ID: mdl-38658344

RESUMO

Processed foods containing soybean or maize are subject to labeling regulations pertinent to genetically modified (GM) foods in Japan. To confirm the reliability of the labeling procedure of GM foods, the Japanese standard analytical methods (standard methods) using real-time PCR technique have been established. Although certain DNA extraction protocols are stipulated as standard in these methods, the use of other protocols confirmed to be equivalent to the existing ones was permitted. In this study, the equivalence testing of the techniques employed for DNA extraction from processed foods containing soybean or corn was conducted. In this study, the equivalence testing of the techniques employed for DNA extraction from processed foods containing soybean or maize was conducted. The silica membrane-based DNA extraction kits, GM quicker 4 and DNeasy Plant Maxi Kit (Maxi Kit), as an existing method were compared. GM quicker 4 was considered to be equivalent to or better than Maxi Kit.


Assuntos
DNA de Plantas , Alimentos Geneticamente Modificados , Soja , Reação em Cadeia da Polimerase em Tempo Real , Zea mays , Zea mays/química , Zea mays/genética , Soja/química , DNA de Plantas/isolamento & purificação , DNA de Plantas/genética , Análise de Alimentos/métodos , Plantas Geneticamente Modificadas/genética , Plantas Geneticamente Modificadas/química , Rotulagem de Alimentos , Japão , Fast Foods/análise , Manipulação de Alimentos/métodos , Alimento Processado
4.
J Hazard Mater ; 470: 134271, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38608593

RESUMO

Rapid and sensitive monitoring of pH and histamine is crucial for bridging biological and food systems and identifying corresponding abnormal situations. Herein, N-doped carbon dots (CDs) are fabricated by a hydrothermal method employing dipicolinic acid and o-phenylenediamine as precursors. The CDs exhibit colorimetric and fluorescent dual-mode responses to track pH and histamine variations in living cells and food freshness, respectively. The aggregation-induced emission enhancement and intramolecular charge transfer result in a decrease in absorbance and an increase in fluorescence, which become readily apparent as the pH changes from acidic to neutral. This property enables precise differentiation between normal and cancerous cells. Furthermore, given the intrinsic basicity of histamine, pH-responsive CDs are advantageous for additional colorimetric and fluorescent monitoring of histamine in food freshness, achieving linearities of 25-1000 µM and 30-1000 µM, respectively, which are broader than those of alternative nanoprobes. Interestingly, the smartphone-integrated sensing platform can portably and visually evaluate pH and histamine changes due to sensitive color changes. Therefore, the sensor not only establishes a dynamic connection between pH and histamine for the purposes of biological and food monitoring, but also presents a novel approach for developing a multifunctional biosensor that can accomplish environmental monitoring and biosensing simultaneously.


Assuntos
Carbono , Colorimetria , Histamina , Pontos Quânticos , Histamina/análise , Carbono/química , Colorimetria/métodos , Concentração de Íons de Hidrogênio , Pontos Quânticos/química , Humanos , Técnicas Biossensoriais/métodos , Espectrometria de Fluorescência , Smartphone , Análise de Alimentos/métodos , Nitrogênio/química , Fluorescência , Corantes Fluorescentes/química
5.
Compr Rev Food Sci Food Saf ; 23(2): e13325, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38532695

RESUMO

This manuscript presents a comprehensive review of high-resolution mass spectrometry in the field of food analysis and metabolomics. We have followed the historical evolution of metabolomics, its associated techniques and technologies, and its increasing role in food science and research. The review provides a critical comparison and synthesis of tentative identification guidelines proposed for over 15 years, offering a condensed resource for researchers in the field. We have also examined a wide range of recent metabolomics studies, showcasing various methodologies and highlighting key findings as a testimony of the versatility of the field and the possibilities it offers. In doing so, we have also carefully provided a compilation of the software tools that may be employed in this type of studies. The manuscript also explores the prospects of high-resolution mass spectrometry and metabolomics in food science. By covering the history, guidelines, applications, and tools of metabolomics, this review attempts to become a comprehensive guide for researchers in a rapidly evolving field.


Assuntos
Análise de Alimentos , Metabolômica , Espectrometria de Massas/métodos , Metabolômica/métodos
6.
Anal Chem ; 96(13): 5170-5177, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38512240

RESUMO

To meet the needs of food safety for simple, rapid, and low-cost analytical methods, a portable device based on a point discharge microplasma optical emission spectrometer (µPD-OES) was combined with machine learning to enable on-site food freshness evaluation and detection of adulteration. The device was integrated with two modular injection units (i.e., headspace solid-phase microextraction and headspace purge) for the examination of various samples. Aromas from meat and coffee were first introduced to the portable device. The aroma molecules were excited to specific atomic and molecular fragments at excited states by room temperature and atmospheric pressure microplasma due to their different atoms and molecular structures. Subsequently, different aromatic molecules obtained their own specific molecular and atomic emission spectra. With the help of machine learning, the portable device was successfully applied to the assessment of meat freshness with accuracies of 96.0, 98.7, and 94.7% for beef, pork, and chicken meat, respectively, through optical emission patterns of the aroma at different storage times. Furthermore, the developed procedures can identify beef samples containing different amounts of duck meat with an accuracy of 99.5% and classify two coffee species without errors, demonstrating the great potential of their application in the discrimination of food adulteration. The combination of machine learning and µPD-OES provides a simple, portable, and cost-effective strategy for food aroma analysis, potentially addressing field monitoring of food safety.


Assuntos
Café , Inocuidade dos Alimentos , Animais , Bovinos , Carne/análise , Contaminação de Alimentos/análise , Análise de Alimentos
7.
Food Chem ; 448: 138994, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38522301

RESUMO

Integrating a pre-enrichment step into electrochemical detection methodologies has traditionally been employed to enhance the performance of heavy metal detection. However, this augmentation also introduces a degree of intricacy into the sensing process and increases energy consumption. In this work, Mo-doped WO3 is grown in situ on carbon cloth by one-step electrodeposition. The electrode detect multiple heavy metal ions simultaneously in the range of 0.1-100.0 µM with LODs ranging from 11.2 to 17.1 nM. The electrode successfully detected heavy metal ions in diverse food samples. This pioneering detection strategy realized the direct and simultaneous detection of multiple heavy metal ions by utilizing the valence property of WO3 and oxygen vacancies generated by molybdenum doping. The Mo-WO3/CC pre-enrichment-free detection electrode boasts straightforward preparation, a streamlined detection procedure, swift response kinetics, and superior performance relative to previously reported electrodes, which makes it possible to develop a portable heavy metal ion detection device.


Assuntos
Técnicas Eletroquímicas , Eletrodos , Contaminação de Alimentos , Metais Pesados , Molibdênio , Tungstênio , Metais Pesados/análise , Contaminação de Alimentos/análise , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Tungstênio/química , Molibdênio/química , Óxidos/química , Limite de Detecção , Análise de Alimentos/instrumentação , Análise de Alimentos/métodos
8.
Molecules ; 29(6)2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38542927

RESUMO

Biomedical and food analysis has always been an important topic that closely relates to health [...].


Assuntos
Análise de Alimentos , Análise de Alimentos/métodos , Espectrometria de Massas/métodos
9.
Food Chem ; 445: 138800, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38382253

RESUMO

In the ongoing pursuit of enhancing food safety and quality through advanced technologies, silver nanoparticles (AgNPs) stand out for their antimicrobial properties. Despite being overshadowed by other nanoparticles in food sensing applications, AgNPs possess inherent qualities that make them effective tools for rapid and selective contaminant detection in food matrices. This review aims to reinvigorate the interest in AgNPs in the food industry, emphasizing their sensing mechanism and the transformative potential of integrating them with artificial intelligence (AI) for enhanced food safety monitoring. It discusses key AI tools and principles in the food industry, demonstrating their positive impact on food analytical chemistry. The interplay between AI and biosensors offers many advantages and adaptability to dynamic analytical challenges, significantly improving food safety monitoring and potentially redefining the landscape of food safety and quality assurance.


Assuntos
Anti-Infecciosos , Nanopartículas Metálicas , Prata/química , Nanopartículas Metálicas/química , Análise de Alimentos , Inteligência Artificial , Anti-Infecciosos/química
10.
Sensors (Basel) ; 24(3)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38339641

RESUMO

Edible insects have been recognised as an alternative food or feed ingredient due to their protein value for both humans and domestic animals. The objective of this study was to evaluate the ability of both near- (NIR) and mid-infrared (MIR) spectroscopy to identify and quantify the level of adulteration of cricket powder added into two plant proteins: chickpea and flaxseed meal flour. Cricket flour (CKF) was added to either commercial chickpea (CPF) or flaxseed meal flour (FxMF) at different ratios of 95:5% w/w, 90:10% w/w, 85:15% w/w, 80:20% w/w, 75:25% w/w, 70:30% w/w, 65:35% w/w, 60:40% w/w, or 50:50% w/w. The mixture samples were analysed using an attenuated total reflectance (ATR) MIR instrument and a Fourier transform (FT) NIR instrument. The partial least squares (PLS) cross-validation statistics based on the MIR spectra showed that the coefficient of determination (R2CV) and the standard error in cross-validation (SECV) were 0.94 and 6.68%, 0.91 and 8.04%, and 0.92 and 4.33% for the ALL, CPF vs. CKF, and FxMF vs. CKF mixtures, respectively. The results based on NIR showed that the cross-validation statistics R2CV and SECV were 0.95 and 3.16%, 0.98 and 1.74%, and 0.94 and 3.27% using all the samples analyzed together (ALL), the CPF vs. CKF mixture, and the FxMF vs. CKF mixture, respectively. The results of this study showed the effect of the matrix (type of flour) on the PLS-DA data in both the classification results and the PLS loadings used by the models. The different combination of flours (mixtures) showed differences in the absorbance values at specific wavenumbers in the NIR range that can be used to classify the presence of CKF. Research in this field is valuable in advancing the application of vibrational spectroscopy as routine tools in food analysis and quality control.


Assuntos
Críquete , Farinha , Animais , Humanos , Farinha/análise , Pós , Análise Espectral/métodos , Análise de Alimentos , Análise dos Mínimos Quadrados , Espectroscopia de Infravermelho com Transformada de Fourier/métodos
11.
Food Chem ; 443: 138577, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38309023

RESUMO

High performance liquid chromatography coupled with post-column derivatization is used for increasing the sensitivity and selectivity of the desirable analytes after the chromatographic separation. The transformation of the analytes can be conducted through the addition of a suitable reagent in the eluted stream or the ultraviolet irradiation of the eluted analytes, forming detectable derivatives for ultraviolet or fluorescence detectors. This review focuses on the developed methods using high performance liquid chromatography coupled with post-column derivatization for the determination of substances in food samples during the last two decades. The significance of the determination of each analyte in foods and the existing guidelines in each case are discussed. Preparation of the samples and the analytical methods are commented. For each analyte, official methods and commercially available systems and reagents are mentioned, as well.


Assuntos
Cromatografia Líquida de Alta Pressão , Análise de Alimentos , Cromatografia Líquida de Alta Pressão/métodos , Análise de Alimentos/métodos
12.
J Agric Food Chem ; 72(9): 4493-4517, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38382051

RESUMO

With the global limited food resources receiving grievous damage from frequent climate changes and ascending global food demand resulting from increasing population growth, perovskite nanocrystals with distinctive photoelectric properties have emerged as attractive and prospective luminogens for the exploitation of rapid, easy operation, low cost, highly accurate, excellently sensitive, and good selective biosensors to detect foodborne hazards in food practices. Perovskite nanocrystals have demonstrated supreme advantages in luminescent biosensing for food products due to their high photoluminescence (PL) quantum yield, narrow full width at half-maximum PL, tunable PL in the entire visible spectrum, easy preparation, and various modification strategies compared with conventional semiconductors. Herein, we have carried out a comprehensive discussion concerning perovskite nanocrystals as luminogens in the application of high-performance biosensing of foodborne hazards for food products, including a brief introduction of perovskite nanocrystals, perovskite nanocrystal-based biosensors, and their application in different categories of food products. Finally, the challenges and opportunities faced by perovskite nanocrystals as superior luminogens were proposed to promote their practicality in the future food supply.


Assuntos
Compostos de Cálcio , Análise de Alimentos , Nanopartículas , Óxidos , Titânio , Estudos Prospectivos , Qualidade dos Alimentos
14.
Eur J Gastroenterol Hepatol ; 36(4): 416-422, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38407849

RESUMO

OBJECTIVE: Food products with <20 mg/kg gluten can be labeled 'gluten-free' according to international regulations. Several antibodies-based ELISAs have been develop to track gluten traces in food products. Among them, R5 and G12 antibody-based ELISAs are the frequently used methods. However, these antibodies have certain limitations. We evaluated the accuracy of G12/A1 antibody-based 'Glutentox ELISA Rapid G12' and compared the results with the current reference method i.e., R5 antibody-based 'Ridascreen R5 ELISA'. METHODS: In the first step, the performance of Glutentox ELISA Rapid G12 kit was inspected by determination of the threshold value i.e., > or <20 mg/kg gluten in different food products. In the second step, quantification accuracy was assessed by quantification of gluten in gluten-free food products spiked with gliadin reference material. RESULTS: In total 47 food products (naturally and labeled gluten-free, and food with traces of gluten) were included. Of them, 29 products were quantified with <20 mg/kg, and 18 with a low level of gluten by both the kits. Six out of 29 gluten-free products were used for the recovery test at different spike levels. Gluten concentration and mean recovery rates of individual kits showed consistency. CONCLUSION: GlutenTox Rapid G12 ELISA could be an appropriate choice for detecting gluten in food products but needs more in-house validation and collaborative tests.


Assuntos
Análise de Alimentos , Glutens , Humanos , Glutens/análise , Análise de Alimentos/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Anticorpos , Gliadina
15.
Food Chem ; 444: 138650, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38330611

RESUMO

Sesame (Sesamum indicum L.) is an important allergenic food whose presence can be the cause of severe allergic reactions in sensitised individuals. In this work, nanoplate digital PCR (ndPCR) was used to develop two methods to detect trace amounts of sesame in processed foods and compared with previously proposed real-time PCR assays. Two independent ndPCR approaches were successfully advanced, achieving sensitivities of 5 and 0.1 mg/kg of sesame in dough/biscuits, targeting the CO6b-1 and ITS regions, respectively. The sensitivity using both targets was improved by one order of magnitude comparing with real-time PCR and was not affected by food processing. CO6b-1 system was not influenced by food matrix, exhibiting similar performance regardless the use of complex matrix extracts or serial diluted DNA. Herein, ndPCR was proposed for the first time for the detection of allergenic foods with the advantage of providing better performance than real-time PCR regarding sensitivity and robustness.


Assuntos
Hipersensibilidade Alimentar , Sesamum , Humanos , Sesamum/genética , Análise de Alimentos/métodos , Reação em Cadeia da Polimerase em Tempo Real , DNA de Plantas/genética , DNA de Plantas/análise , Alérgenos/genética , Alérgenos/análise
16.
Anal Chim Acta ; 1292: 342259, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38309842

RESUMO

BACKGROUND: Heavy metal pollution has become one of the world's most important environmental pollution, especially Hg2+ is enriched, it is easy to enter the human body through the food chain, bind to the sulfhydryl group in the protein, cause mercury poisoning. Traditional methods for detecting Hg2+ have obvious drawbacks, such as poor selectivity and long detection time. Fluorescence detection has attracted attention because of its good sensitivity and specificity detection ability. In previously reported probes for detecting Hg2+, Cu2+ often interferes. Therefore, it is of great practical significance to synthesize a fluorescent probe that can distinguish between Hg2+ and Cu2+. RESULTS: We have successfully synthesized the probe DFS, a fluorescent probe that can differentially detect Hg2+ and Cu2+, and the probe DFS has good selectivity and anti-interference ability for Hg2+ and Cu2+. The fluorescence intensity at 530 nm increased rapidly when Hg2+ was detected; during the Cu2+ detection, the fluorescence intensity at 636 nm gradually decreased, fluorescence quenching occurred, and the detection limits of Hg2+ and Cu2+ were 7.29 × 10-9 M and 2.13 × 10-9 M, respectively. Through biological experiments, it was found that probe DFS can complete the fluorescence imaging of Hg2+ and Cu2+ in Staphylococcus aureus and HUVEC cells, which has certain research value in the field of environmental monitoring and microbiology, and the probe DFS has low cytotoxicity, so it also has broad application prospects in the field of biological imaging. In addition, the probe DFS also has good applicability for Hg2+ and Cu2+ detection in actual samples. SIGNIFICANCE AND NOVELTY: This is a fluorescent probe that can distinguish between Hg2+ and Cu2+, the fluorescence emission peak appears at 530 nm when Hg2+ is detected; when detecting Cu2+, fluorescence quenching occurs at 636 nm, the fluorescence emission peak distance between Hg2+ and Cu2+ differs by 106 nm. This reduces mutual interference between Hg2+ and Cu2+ during detection, it provides a new idea for the detection of Hg2+ and Cu2+.


Assuntos
Corantes Fluorescentes , Mercúrio , Humanos , Corantes Fluorescentes/análise , Análise de Alimentos , Mercúrio/análise , Sensibilidade e Especificidade , Bactérias , Espectrometria de Fluorescência
17.
Compr Rev Food Sci Food Saf ; 23(1): e13301, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38284587

RESUMO

In recent years, the food industry has shown a growing interest in the development of rapid and nondestructive analytical methods. However, the utilization of a solitary nondestructive detection technique offers only a constrained extent of physical or chemical insights regarding the sample under examination. To overcome this limitation, the amalgamation of spectroscopy with data fusion strategies has emerged as a promising approach. This comprehensive review delves into the fundamental principles and merits of low-level, mid-level, and high-level data fusion strategies within the domain of food analysis. Various data fusion techniques encompassing spectra-to-spectra, spectra-to-machine vision, spectra-to-electronic nose, and spectra-to-nuclear magnetic resonance are summarized. Moreover, this review also provides an overview of the latest applications of spectral data fusion techniques (SDFTs) for classification, adulteration, quality evaluation, and contaminant detection within the purview of food safety analysis. It also addresses current challenges and future prospects associated with SDFTs in real-world applications. Despite the extant technical intricacy, the ongoing evolution of online data fusion platforms and the emergence of smartphone-based multi-sensor fusion detection technology augur well for the pragmatic realization of SDFTs, endowing them with formidable capabilities for both qualitative and quantitative analysis in the realm of food analysis.


Assuntos
Análise de Alimentos , Indústria Alimentícia , Análise Espectral/métodos , Análise de Alimentos/métodos
18.
Biosens Bioelectron ; 248: 115947, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38181518

RESUMO

Owing to their advantages such as great specificity, sensitivity, rapidity, and possibility of noninvasive and real-time monitoring, electrochemical cell-based biosensors (ECBBs) have been a powerful tool for food analysis encompassing the areas of nutrition, flavor, and safety. Notably, the distinctive biological relevance of ECBBs enables them to mimic physiological environments and reflect cellular behaviors, leading to valuable insights into the biological function of target components in food. Compared with previous reviews, this review fills the current gap in the narrative of ECBB construction strategies. The review commences by providing an overview of the materials and configuration of ECBBs, including cell types, cell immobilization strategies, electrode modification materials, and electrochemical sensing types. Subsequently, a detailed discussion is presented on the fabrication strategies of ECBBs in food analysis applications, which are categorized based on distinct signal sources. Lastly, we summarize the merits, drawbacks, and application scope of these diverse strategies, and discuss the current challenges and future perspectives of ECBBs. Consequently, this review provides guidance for the design of ECBBs with specific functions and promotes the application of ECBBs in food analysis.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Eletrodos , Análise de Alimentos
19.
Food Chem ; 442: 138466, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38245987

RESUMO

There are various analytical techniques available to address the growing interest in the composition of food products. LC-HRMS(/MS) is the most comprehensive technique, providing detailed information at the molecular level. However, given the vast number of different molecules encountered in food products, it is important to obtain a global overview of the dataset before focusing on similarities and differences. Therefore, a convergent strategy was employed, going from non-targeted to targeted analysis, with insightful data representations, most notably Molecular Barcode. Additionally an intermediate, semi-targeted analysis was defined, aimed at the specific detection of animal tissue in food products, using pG+ and related fragments after all ion fragmentation. The use of Molecular Barcode as a starting point to obtain relevant molecular data was also demonstrated. In conclusion, the convergent approach facilitates the design of suitable targeted methods, either to discriminate between samples or to find a generic target.


Assuntos
Análise de Alimentos
20.
Food Chem ; 439: 138140, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38061298

RESUMO

Rose tea infusion has gained popularity worldwide due to its health benefits. However, it is known that tea plants can be contaminated with heavy metals including copper. Hence, an accurate and applicable analytical method namely emulsification liquid-liquid microextraction based deep eutectic solvent - flame atomic absorption spectrometry (ELLME-DES-FAAS) was proposed to determine copper at trace levels in rose tea samples. Under the optimum experimental conditions, analytical figures of merit for the developed method were examined, and dynamic range, limit of detection (LOD) and limit of quantification (LOQ) were found to be 5.07-246.61 µg/kg (mass-based) with 0.9992 coefficient of determination, 2.50 µg/kg and 8.32 µg/kg, respectively. A matrix matching calibration strategy was employed to boost recovery results, and the acceptable recovery results were recorded between 95.9 % and 118.4 %. According to recovery results, the developed analytical method can be safely employed to determine the concentration of copper in rose tea samples accurately.


Assuntos
Microextração em Fase Líquida , Poluentes Químicos da Água , Cobre/análise , Microextração em Fase Líquida/métodos , Espectrofotometria Atômica/métodos , Análise de Alimentos/métodos , Solventes/química , Limite de Detecção , Chá/química , Poluentes Químicos da Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...